T-45C TS, ADV, & IUT NFamFP-02
Night Emergency Procedures
12. Undervoltage sensing unit has a 1.5 sec
time delay to filter out undervoltage
transients
13. Inverter automatically drops off-line to
conserve battery power
14. If one inverter fails the other inverter will
automatically come on-line, if necessary, to
power the AC Essential Services Bus
VI. Double inverter failure 1.8.1.3.1.3.2
Sg 6, fr 1
NIGHT EMERGENCY
PROCEDURES
*
Wheel brake failure
Question 2 1.8.1.3.1.3.2
*
Failure to reach line speed
What NAV equipment will be inoperative if you
*
Takeoff abort
have a double inverter failure?
*
Engine failure on takeoff
*
ANSWER:
battery voltage
1. VOR
*
Double inverter failure
2. ILS
*
Total electrical failure
3. Marker beacon
*
GINA failure
4. TACAN
*
TACAN bearing failure
5. HSI
*
NORDO
*
Inadvertent IMC
*
Lost aircraft situations
Sg 6, fr 2
A. Indications
1.
MSTR ALERT light flashes
2.
Caution tone sounds in headset
3.
AC INVERTER caution light illuminates
DOUBLE INVERTER FAILURE
4.
Inoperative AC instruments
a.
Radar altimeter
b.
HSI
(9-99) Original
Page 2-15