T-45C TS, ADV & IUT EMFP-04
Engine and Hydraulic Emergency Procedures
d.
Emergency Hydraulic system pressure (HYD 2
Overlay 3
pressure gauge) less than 600 psi
e.
HYD FAIL warning light illuminated
Overlay 4
Sg 2, fr 19
NOTE: The HYD FAIL warning light will illuminate
Fig 8: HYD FAIL
with the HYD 1, HYD 2, and emergency HYD
Warning/Caution
system failure. For the HYD FAIL warning light to
Light Logic
illuminate, HYD 1 system pressure must be less
than 600 + 50 psi, HYD 2 system pressure less
than 1,660 + 110 psi and the emergency HYD
system pressure must be less than 600 + 50 psi.
Figure 8: HYD FAIL WARNING/CAUTION LIGHT LOGIC
Original (9-98)
Page 4-16