| CHAPTER 1, FOOD SAFETY
4-2.9 Warewashing Sinks and Drainboards, Self-draining
Sinks and drainboards of warewashing sinks and machines shall be self-
draining.
4-2.10 Sanitizing Solutions, Testing Devices
The concentration of sanitizing solution(s) shall be verified with a test
kit or other device that accurately measures the concentration in mg/L or
ppm.
4-2.11 Warewashing Equipment, Cleaning Frequency
Warewashing machines; the compartments of sinks, basins, or other
receptacles used for washing and rinsing equipment and utensils will be
cleaned:
a. Before use;
b. Throughout the day at a frequency necessary to prevent
recontamination of equipment and utensils and to ensure that the equipment
performs its intended function; and
c. At least every 24 hours.
4-2.12 Warewashing Equipment, Clean Solutions
The wash, rinse, and sanitize solutions shall be maintained free of food or
other organic matter that affect solution performance.
4-2.13 Manual Warewashing Equipment, Wash Solution Temperature
The temperature of the wash solution in manual warewashing equipment shall
be maintained at not less than 110oF (43oC) unless a different temperature
is specified on the cleaning agent manufacturer's label instructions.
4-2.14 Mechanical Warewashing Equipment, Wash Solution
Temperature
a. The temperature of the wash solution in spray type warewashers that
use hot water to sanitize may not be less than:
(1) For a single tank, stationary rack, single temperature machine,
165 F (74oC);
o
(2) For a single tank, conveyor, dual temperature machine, 160oF
(71oC);