T-45C TS, ADV & IUT OCFFP-01
Out-of-Control Flight
(3) Extended usage of left MFDs beyond 2
minutes (timer cycle) will reduce power
available for GTS engine airstart attempts
5.
Left MFDs, DEU, SADS, GINA, DEP drop off-line
whenever GTS Button is depressed. To regain
functionality of those systems
a.
(If DP Switch not previously positioned in
ORIDE) DP switch: ORIDE
b.
(If DP Switch already postioned in ORIDE)
6.
At 19 volts (aproximately)
a.
Left MFDs, DEU, SADS, GINA, DEP drop off-
line
b.
Cannot return any MFDs, DEU, SADs, GINA,
DEP on-line
B. After a successful airstart
1.
All systems should return to normal operations
2.
If electronic displays are not fully correct, place DP
switch to RESET (spring-loads back to NORMAL).
Systems will "reboot"
C. If engine flames out again
1.
Fewer than the "normal" number of 3 guaranteed
GTS airstarts may be possible do to low battery
voltage
2.
Use DP ORIDE function, judiciously, in light of
limited available battery power
Original (9-98)
Page 1-19