T-45C TS, ADV & IUT EMFP-02
Start, Gound, and Takeoff Emergency Procedures
III. HOT Start 1.4.2.7.2
A. Indications
1. EGT exceeds 550 C (overshoot of 20 C for 10
seconds)
B. Procedures - Refer to Part V, Chapter 13, Ground
Emergencies, of the T-45C NATOPS
IV. HUNG Start 1.4.2.5.1/1.4.2.5.2
A. Indications
1. RPM Stabilizes below 52%
2. EGT continues to rise towards starting limit of 550 C
B. Procedures - Refer to Part V, Chapter 13, Ground
Emergencies, of the T-45C NATOPS
V. GTS Fire 1.4.2.2.2
A. Indications
1. Outside the aircraft - the plane captain points behind
the canopy at the GTS and gives the Lazy 8 signal.
2. Inside the aircraft
a. MASTER ALERT flashes
b. Warning tone sounds
c. GTS FIRE Warning light illuminates
B. Procedures - Refer to Part V, Chapter 12, General
Emergencies, of the T-45C NATOPS
Original (9-98)
Page 2-7