UJPT BIFP-09 & E2-C2 BIFP-05
Instrument Failures
Sg 6, fr 1
Sg 6, fr 2
INSTRUMENT FAILURES
*
SAHRS Failure
*
HSI Failure
OFF
CLI
MB
*
ADI Failure
*
Turn and Slip Indicator Failure
*
Pitot Static Malfunctions
ULL
C
AG
*
Standby Gyro Failure
*
AOA Indicator Failure
FAILED 3" STANDBY GYRO / FAILED 2"
STANDBY GYRO
VI. Standby Gyro Failure 1.8.1.7.6.2
A.
Failure indications
1.
Red "OFF" flag visible
2.
Erroneous indication
CAUTION: "OFF" flag signifies only a loss of power or indication that the
2 inch gyro is in the "cage-locked" position.
B.
Failure of standby gyro not a significant problem if ADI is functional
C.
1.
3 inch gyro - up to 3 minutes
2.
2 inch gyro - minimum of 9 minutes
D.
Procedure
1.
Use ADI
2.
Check electrical system
3.
Check caging knob position (2 inch gyro)
4.
Watch for possible progressive failure
(03-97) Original