T-45C TS, ADV & IUT ENG-27/ENG-28
Engineering Review
(d) At starter cut-out speed (45% rpm)
Sg 14, fr 14
Engine Start Sequence
(i)
Start control unit shuts down GTS
and GTS and READY advisory
lights extinguish
(ii) Engine ignition units deenergize
(may not occur until after N2 rpm
above 61%)
(6) When RPM and EGT stabilize, check:
(a) All warning/caution panel lights - OUT
EXCEPT HYD 2, CANOPY (if open or
unlocked), AND OXYGEN
(b) RPM - NOTE, APPROXIMATELY
52%
(c) EGT - NOTE, 450 DEGREES C
MAXIMUM
Sg 14, fr 15
e.
Post-start
Engine Start Sequence
(1) Throttle - ADVANCE SLOWLY TO 70%
RPM
CAUTION: Following a start, do not
advance the throttle rapidly before the
bleed valve closes, as there is a
possibility that the engine will overheat.
Once the bleed valve is closed there are
no restrictions on the rate of throttle
movement.
(2) FUEL CONTROL switch - MANUAL
M FUEL advisory light illuminates. Note
engine RPM may decrease by up to 6%
(9-98) Original
Page 27-144