| APPENDIX B
T-1A OPERATING LIMITS STUDY AID
GENERATOR LIMITS
TWO GENS UP TO FL410 -------------------------------------------------------------------- 280 AMPS
ONE GEN FL325 TO FL410 ------------------------------------------------------------------ 280 AMPS
ONE GEN UP TO FL325 ---------------------------------------------------------------------- 400 AMPS
MIN VOLTS FOR BATTERY START ------------------------------------------------------ 22 VOLTS
MAX GENERATOR LOAD PRIOR TO SECOND ENGINE START ----------------- 150 AMPS
AIRSPEED LIMITS
FLAPS
10 - 0 DEGREES (T/O) ----------------------------------------------------------------- >= 130 KIAS
0 - 10 DEGREES (LDG) ---------------------------------------------------------------- <= 200 KIAS
10 - 30 DEGREES ----------------------------------------------------------------------- <= 170 KIAS
30 ------------------------------------------------------------------------------------------ <= 165 KIAS
LDG GEAR ---------------------------------------------------------------------------------------- 200 KIAS
LDG LTS ------------------------------------------------------------------------------------------- 200 KIAS
WSHLD WIPERS -------------------------------------------------------------------------------- 200 KIAS
EMERGENCY GEAR EXTENSION ---------------------------------------------------------- 150 KIAS
(RECOMMENDED)
MAX TIRE SPEED (GROUND) --------------------------------------------------------------- 165 KIAS
MIN CONTROL SPEED (GROUND) ---------------------------------------------------------- 88 KIAS
MIN CONTROL SPEED (IN FLIGHT) -------------------------------------------------------- 89 KIAS
FUEL LIMITS
EMERGENCY FUEL ----------------------------------------------------------------------------- 300 LBS
MINIMUM FUEL DUAL ------------------------------------------------------------------------ 500 LBS
OPERATING LIMITS STUDY AID
B-1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |