T-45A UJPT, E2-C2, ADV, & IUT Eng-07
Electrical
II.
Electrical system operational characteristics
Sg 2, fr 1
1.4.4.2.1, 1.4.4.3
Lesson Organization
A.
DC power system: consists of two batteries,
generator, voltage regulator, overvoltage unit,
Electrical System Block Diagram
undervoltage unit, and three 28 VDC buses
1.
Power generation
a.
Main electrical power supplied by 28
Overlay 1
VDC brushless generator
Generator
(1) During ground starts, the
GENERATOR warning light will
extinguish when a suitable DC
output is obtained 25-25.2 VDC (at
approximately 42% rpm); White
Paper: may occur as high as 61%
(weak permanent magnet in
generator) (no big deal - Brits)
b.
As engine rpm or electrical loads
Overlay 2
change, the voltage regulator controls
Voltage Regulator
output voltage to 28.2-29.2 VDC by
adjusting generator excitation voltage
c.
Overvoltage protection unit monitors
Overlay 3
Overvoltage Unit
from exceeding 30.2 VDC by shutting
down generator
d.
If generator goes off-line
(1) MSTR ALERT light flashes
(2) GENERATOR warning light on
WCP illuminates
(3) Warning tone sounds
NOTE: The MSTR ALERT light
and warning tone may be canceled
by pressing the MSTR ALERT
light.
Page 7-8