T-45A UJPT, E2-C2, ADV, & IUT Eng-01
Introduction to NATOPS & T-45A Configuration
C.
Advisory panel: green lights provide system
Sg 5, fr 3
status requiring awareness and possible action
GTS
ROTATION
D.
Centralized warning system master test
SPDBRK
SPD BRK FULL
1.
MASTER TEST switch used to test CWS
ECA
lights and tones
MANUAL FUEL
NOSE WHL STR
ANTI-SKID
a.
LAMP: illuminates all warning, caution,
ADVISORY PANEL
and advisory lights; also tests fire
warning system
b.
TONE: sequentially generates four
audio tones--warning, caution, wheels
up, and weapons release
E.
Intercom system (ICS) interface
1.
Any warning condition detected by CWS
causes ICS to generate warning tone in
headset
a.
Two-tone warble
b.
Continues until MSTR ALERT switch/
light is pressed
2.
Any caution condition detected by CWS
causes ICS to generate caution tone in
headset
a.
Beeping monotone
b.
Lasts for 1 second, unless canceled
first by either crew member by
pressing MSTR ALERT switch/light
3.
Additionally, stall warning, low altitude
warning, and simulated gun firing tones are
provided
(8-03) Original
Page 1-30