T-45C TS, ADV & IUT ENG-03
Electrical System Malfunctions
REFRESHER
Recall:
Fig 1: Electrical
*
Normal operation of the electrical system from Eng-02
System Diagram
*
Electrical malfunction CWS indicators include the MASTER
ALERT light, GENERATOR warning light, and AC INV
caution light
*
Location and function of electrical system indicators and
switches from Eng-02
PRESENTATION
I.
Single/double AC inverter failure 1.8.1.3.1.2.1, 1.8.1.3.1.3.1
NOTE: AC inverter malfunctions may be transient in nature.
If the input or output of an inverter is out of tolerance, the
defective inverter will go off-line, and the other inverter will
take control of the inverter functions. If the defective inverter
can be reset, its failure is considered to be transient.
A.
Single inverter failure
Fig 2: AC Inverter
1.
Indications
Failure
a.
MASTER ALERT flashes
b.
Caution tone sounds
c.
AC INV caution light illuminates
NOTE: The AC inverters are redundant (one
backs up the other), the loss of one inverter will
not affect the operation of essential AC
services.
Page 3-3
Original (9-98)