T-45C TS, ADV & IUT ENG-09
Hydraulic System
Sg 4, fr 5
b.
Physical: thermal relief valve, spool valve,
HYD 2 RESET Button
NOTE: The emergency package assembly
isolates the HYD 2 EDP from the system when
the RAT is deployed. To regain HYD 2 EDP
pressure (and stow the RAT), the HYD 2
RESET button must be pressed.
C.
Emergency hydraulic system: RAT
Sg 4, fr 6, p 1
Hydraulic System
1.
Deployment
Block Diagram
a.
Falling pressure in HYD 2 is sensed by the
emergency package assembly
b.
Emergency package assembly directs RAT
accumulator pressure to RAT actuator, raising
RAT into airstream
2.
Operation
Overlay 1
RAT Actuator/RAT
NOTE: The capability of the RAT to provide
hydraulic power for controllable flight during a total
hydraulic pressure loss has not been determined.
Safe ejection envelopes may be exceeded if control
is lost during a landing attempt on emergency
hydraulic power. Landing approaches on
emergency hydraulic power alone should not be
attempted.
a.
RAT output regulated by cutout
(1) Cutout shuts off RAT output at rising
pressure of 3000 psi
(2) Cutout connects output of RAT at falling
pressure of 2500 psi
b.
RAT charges accumulator
Overlay 2
c.
Supplies HYD 2 flight control services through
RAT Accumulator
emergency package assembly
(9-98) Change 1
Page 9-30