  158    159    160    161    162  163  164    165    166    167    168  
T-45C TS, ADV & IUT EMFP-09
Electrical and Indicator Emergency Procedures
REFRESHER
Recall the electrical, environmental and indicator emergency
procedures you learned during EMFP-10.
PRESENTATION
I.
Single Inverter Failure 1.8.1.3.1.2.2
A. Indications
1.
MASTER ALERT flashes
2.
Caution tone sounds
3.
AC INV caution light illuminates
4.
VOR/ILS/Marker Beacon receiver and Radar
Altimeter lost
B. Procedures - Refer to Part V, Chapter 12, General
Emergencies, of the T-45C NATOPS
II.
Double Inverter Failure 1.8.1.3.1.3.2
A. Indications
1.
MASTER ALERT flashes
2.
Caution tone sounds
3.
AC INV caution light illuminates
4.
VOR/ILS/Marker Beacon receiver and Radar
Altimeter lost.
5.
C AUG caution light illuminates below 217 knots.