  144    145    146    147    148  149  150    151    152    153    154  
T-45C TS, ADV & IUT EMFP-08
Electrical and Indicator Emergency Procedures
2.
Procedures - See NATOPS
Sg 1, fr 10
D.
Cockpit lighting failure 1.8.1.3.5.2
Cockpit Lighting
Failure
1.
Indications: fails to illuminate when selected ON
2.
Procedures
a.
Maintain control using outside visual references
b.
Emergency flood lighting automatically
activated
c.
Illuminate cockpit using flashlight
d.
Check for flags on standby instruments
e.
Dimmer controls - FULLY CLOCKWISE
f.
Check BATT switches - ON
g.
If unable to restore lighting
(1) Verify malfunction is related to electrical
system
(2) Land as soon as practical
E.
Electrical fire 1.8.1.3.1.5
1.
Indications
a.
Smoke or acrid odors
b.
Associated system fails when circuit breaker
pops
c.
Fluctuating instrument readings
d.
Flickering lights
2.
Procedures - See NATOPS